BRIDGE CONSOLE
September 1, 2009 by admin
Manoeuvring console
N.1 Console equipped with:
(size: H 120 cm; W 80 cm; L 160 cm)
N.1 Steering control,
N.2 small Steering control,
N.2 rudder angle indicator;
N.1 Steering selector;
N.1 Engine Control;
N.2 indicator step eliche;
N.2 RPM indicators;
N.2 bow thruster panel;
N.1 Alarm panel;
N.1 Gyrocompass;
N.1 Autopilot;
N.1 lights managing panel;
N.1 Monitor;
N.1 View Selection;
N.1 Electronic interface,
N.1 PC.
ECDIS / RADAR consolE
N.3 Multifunction console equipped with:
(size: H 120 cm; W 90 cm; L 85 cm)
N.1 Monitor lcd 22″ 1680 X 1050 16:9,
N.1 keyboard whit track-ball,
ANCHOR CONSOLE
N.1 Console equipped with:
(size: H 120 cm; L 80 cm; L 85 cm)
N.1 Monitor lcd 12″,
N.1 anchor panel to managing,
N.1 Electronic interface.
BINOCULAR CONSOLE
N.1 Corner console dedicated to an independent visual channel that can be used as binocular, using the joystick it is possible to change bearing and to zoom in/out:
N.1 Monitor lcd 22″ 1680 X 1050 16:9,
N.1 Joystick analogical 2 way ,
N.2 Push button,
N.1 Electronic interface.
GPS console
N.1 Corner console whit real equipement whit NMEA Standard interface
SOFTWARE SPECIFICATION
Driver Ni-Engine
Driver to manage and manipulate Analog e Digital signal acquired from National Instruments devices DAQ series.
Features:
- User friendly interface
- Not limited devices
- Not limited Input and output channels
- Output conditioning
- Output Ethernet – UDP protocol
WorkFlow:
With a simple list is possible to assign name in text format at each signals and channels.
Linear conditioning for each Output signal.
NI_Engine creates a message with variable, value and other control fields for each signal and send the message in a defined interval.
The text message was send in UDP protocol at an IP address and Port defined in a configuration file.
AUTOMATION HARDWARE SPECIFICATION
SYSTEM
All the bridge components are fully cabled, interfaced with the Control PC via a standard interface (USB or Ethernet). The PC interacts with the physical components of the bridges and talk with the simulation system via Ethernet Standard UDP
THE FIELD INTERFACE
I/F Standard (USB or Ethernet) to talk with the PC software driver
Modules to interface the field:
- 48 Digital Input
(to read the push button / switch activation) - 48 Digital Output
(to turn on/off the signaling leds) - 8 Analog Input Channel +/- 10V
(to read the position of main controls like rudder, power levers, …) - 8 Analog Output Chanel +/- 10V
(to manage analogical indicators like Engine RPM, Rudder indicator, …)
110-240 VAC
DIN Rail mount
THE PHYSICAL INPUT DEVICES
- Main Rudder
(wheel and electronic helm) - 2 potentiometric controls for manage separately the rudders
- Control Head for two engines
- 8 panels with buttons/switches/signaling leds
(chain / alarms / point of view selector / autopilot / lights / thrusters / rudders selection)
Binocular control panel with analogical Joystick and zoom buttons